INFLUENCE OF WATER DISCHARGE USING THE „T”, „Z”, „O” AND „INVERTED U” LETTERS TECHNIQUE ON ITS DISTRIBUTION IN A CONFINED SPACE

Alexandru-Florin CHIOJDOIU, Ion ANGHEL, Carmen Anca SAFTA, Adrian SIMION

Abstract


Knowing how water is distributed after its discharging in a confined space is necessary to make firefighting more efficient. Using the „T”, „Z”, „O” and „inverted U” letters technique to discharge water inside a test room, on the opposite wall, in the absence of fire, several main conclusions can be drawn: near the wall diametrically opposite the area from which the water was discharged, the highest values of the  water volume accumulated were recorded; from the smallest recorded water loss point of view, it is recommended to discharge the water in the form of the „Z” letter, followed by discharging in the form of the „T”, „O” and „inverted U” letters.

Full Text:

PDF

References


Corbett, G., Fire Engineering’s Handbook for Firefighter I and II, Fire Engineering Books, 2009.

Klaene, B. J., Sanders. R. E., Structural Fire Fighting. National Fire Protection Association, 2000.

Johansson, N., Svensson, S., Review of the use of fire dynamics theory in fire service activities, Fire Technology, 55, 81-103, 2019.

Kerber. S., Impact of Ventilation on Fire Behavior in Legacy and Contemporary Residential Construction. Report, Underwriters Laboratories, 2014.

Kerber. S., Study of the effectiveness of fire service vertical ventilation and suppression tactics in single family homes. Report, Underwriters Laboratories, 2013.

Kerber S., Zevotek, R., Study of residential attic fire mitigation tactics and exterior fire spread hazards on firefighter safety. Report, Underwriters Laboratories, 2014.

Kerber, S., Utilizing research to enhance fire service knowledge. Doctoral University of Lund, 2020.

Löffel, S., Walls, R., Development of a full-scale testing methodology for benchmarking fire suppression systems for use in informal settlement dwellings, International journal of disaster risk reduction, 45, 101451, 2020.

CHIOJDOIU, A.-F., ANGHEL, I., PANAITESCU, V. N., Analiza comparativă a influenței principalilor parametri asupra eficientizării stingerii cu apă a incendiilor, Revista Romana de Inginerie Civila, Volumul 1, Numarul 2, 2020.

Särdqvist, S., Water and other extinguishing agents, Karlstad, Sweden: Räddnings Verket, 2002.

Gsell, J., Assessment of Fire Suppression Capabilities of Water Mist – Fighting Compartment Fires with the Cutting Extinguisher, Pg. Dip. Msc. Fire Safety Engineering, Academic, 2009 / 2010.

http://cfbt-us.com/wordpress/?p=1299, accesat în data de 06.01.2020, ora 22.15.

Zevotek, R., Stakes, K., Willi, J., Impact of Fire Attack Utilizing Interior and Exterior Streams on Firefighter Safety and Occupant Survival: Full Scale Experiments, 2018.

Walton, W. D., Walton, W. D., Suppression of wood crib fires with sprinkler sprays: Test results, US Department of Commerce, National Bureau of Standards 1988.

Abdulrahman, S. A., Chetehouna, K., Cablé, A., Skreiberg, Ø., Kadoche, M., A review on fire suppression by fire sprinklers, Journal of Fire Sciences, 39(6), 512-551, 2021.

Santangelo, P. E., Jacobs, B. C., Ren, N., Sheffel, J. A., Corn, M. L., Marshall, A. W., Suppression effectiveness of water-mist sprays on accelerated wood-crib fires, Fire safety journal, 70, 98-111, 2014.

Liu, Z., Kim, A. K., Carpenter, D., A study of portable water mist fire extinguishers used for extinguishment of multiple fire types, Fire safety journal, 42(1), 25-42, 2007.

Chang, W. Y., Fu, P. K., Chen, C. H., Shu, Y. L. Evaluating the performance of a portable water–mist fire extinguishing system with additives, Fire and Materials: An International Journal, 32(7), 383-397, 2008.

Pancawardani, F., Arini, D., Yunindar, R. P., Ramadhan, M. L., Imran, F. A., Nugroho, Y. S., Analysis of water mist fire suppression system applied on cellulose fire, Procedia engineering, 170, 344-351, 2017.

Noaki, M., Delichatsios, M. A., Yamaguchi, J. I., Ohmiya, Y., Heat release rate of wooden cribs with water application for fire suppression, Fire Safety Journal, 95, 170-179, 2018.

Rappsilber, T., Below, P., Krüger, S., Wood crib fire tests to evaluate the influence of extinguishing media and jet type on extinguishing performance at close range, Fire Safety Journal, 106, 136-145, 2019.

Takahashi, S., Experiments and Theory in the Extinction of a Wood Crib, In Fire Safety Science-Proceedings of the First International Symposium (pp. 1197-1206), 1986.

Collin, A., Suzanne, M., Testa, F., Doelsch, P., Acem, Z., Thiry‐Muller, A., Boulet, P., Quantification of radiative attenuation provided by fire hose nozzles, Fire and materials, 46(7), 1034-1044, 2022.

Rathnayake, U., Karunaratne, T. L., Han, S., Lau, D., Chow, C. L., Experimental investigation on thermal performance of water wall systems exposed to fire, Indoor and Built Environment, 32(1), 170-182, (2023).

Salyers, B. E., Spray characteristics from fire hose nozzles (Doctoral dissertation), 2010.

Dai, H. Y., Hasegawa, M., Kawabata, N., Seike, M., Chien, S. W., Shen, T. S., Applying large-scale PIV to water monitor discharge experiment, Fire Safety Journal, 120, 103110, 2021.

Hatton, A. P., Osborne, M. J., The trajectories of large firefighting jets, International Journal of Heat and Fluid Flow, 1(1), 37-41, 1979.

Stowell F. M., Murnane, L., Essential of Firefighting and Fire Department Operations, Brady Publishing, International Fire Service Training Association, 6 edition, 2013.

Ghid privind tehnica şi tactica stingerii incendiilor, Nivel I - Tura de Serviciu, ISU 04, 2013.

Weinschenk, C., Stakes, K., Zevotek, R., Impact of Fire Attack Utilizing Interior and Exterior Streams on Firefighter Safety and Occupant Survival: Water Mapping, 2017.

Weinschenk, C., Stakes, K., Zevotek, R., Impact of Fire Attack Utilizing Interior and Exterior Streams on Firefighter Safety and Occupant Survival: Air Entrainment, 2017.

Willi, J., Weinschenk, C., Madrzykowski, D., Impact of hose streams on air flows inside a structure, Nist technical report 1938, National Institutes of Standards and Technology, Gaithersburg, MD, 2016.

Bryant, R. A., A comparison of gas velocity measurements in a full-scale enclosure fire, Fire Safety

Journal, 44:793–800, 2009.

Zevotek, R., Kerber, S., Study of the effectiveness of fire service positive pressure ventilation during fire attack in single family homes incorporating modern construction practices, Technical report, UL Firefighter Safety Research Institute, Columbia, MD, 2016.

Knapp, J., Pillsworth, T., White, S., Nozzle Tests Prove Fireground Realities, Part 1. Fire Engineering,

February 2003.

Knapp, J., Pillsworth, T., White, S., Nozzle Tests Prove Fireground Realities, Part 2. Fire Engineering,

September 2003.

Knapp, J., Pillsworth, T., White, S., Nozzle Tests Prove Fireground Realities, Part 3. Fire Engineering, September 2003.

Inc. Task Force Tips, Range and trajectory data of hand held nozzles, Technical report, Valparaiso, IN, 1994.

Nfpa 1963: Standard for fire hose connections. Standard, National Fire Protection Association, 2014.

A Firefighter’s Guide to Nozzles, Valparaiso, IN, 1, 2001.

Akron Brass MFG. CO., Chief nozzle flow, Technical report, Elkhart, IN.

Schwille, J. A., Kung, H., Hjohlman, M., Laverick, G. E., Gardell, G. W., Actual Delivered Density Fire Test Apparatus for Sprinklers Protecting High Commodity Storage, Fire Safety Science, 8:823–833, 2005.

National Fire Protection Association, Standard for the Installation of Sprinkler Systems in One and Two Family Dwelling and Manufactured Homes, Quincy, Massachusetts. NFPA 13D, 2006.

Neamtu, C., Anghel, I., Chiojdoiu, A.-F., Buna, Z., Trofin, A., Dragomir, D., Automatic fire extinguishing system using “T”, “Z”, “O” letters technique based on a parallel structure, Acta Technica Napocensis, Series: Applied Mathematics, Mechanics, and Engineering, Vol. 62, Issue III, September, 2019.

www.akrnbrass.com.

Suprastructura pentru autospeciala pentru lucrul cu apă și spumă de 2 tone, Carte tehnică, Instrucțiuni de utilizare și întreținere, rev. 1, Rădăcini Motors.

Manualul utilizatorului, Pompe centrifuge cu

dispozitive de amorsare pentru stingerea incendiilor, Rădăcini Motors.