HEMODIAFILTRATION WITH SELF-CLEANING SYSTEM
Abstract
Full Text:
PDFReferences
Henderson LW: Biophysics of ultrafiltration and hemofiltration; in Maher JF (ed): Replacement of Renal Function by Dialysis. Dordrecht, Kluwer Academic, 1989, pp 300-326. Available at https://karger.com/bpu/article/40/Suppl.%201/2/48636/Hemodiafiltration-Technical-and-Clinical-Issues [ accessed at 30 March 2024]
Ledebo I: On-line preparation of solutions for dialysis: practical aspects versus safety and regulations. J Am Soc Nephrol 2002;13(suppl 1):S78-S83.
Ronco C, Cruz D: Hemodiafiltration history, technology, and clinical results. Adv Chronic Kidney Dis 2007;14:231-243.
Ronco C, Heifetz A, Fox K, Curtin C, Brendolan A, Gastaldon F, et al: Beta 2-microglobulin removal by synthetic dialysis membranes. Mechanisms and kinetics of the molecule. Int J Artif Organs 1997;20:136-143.
Vienken J, Ronco C: New developments in hemodialyzers. Contrib Nephrol 2001;133:105-118.
Canaud B, Barbieri C, Marcelli D, Bellocchio F, Bowry S, Mari F, Amato C, Gatti E: Optimal convection volume for improving patient outcomes in an international incident dialysis cohort treated with online hemodiafiltration. Kidney Int 2015, Epub ahead of print.
Lévesque R, Marcelli D, Cardinal H, Caron ML, Grooteman MP, Bots ML, Blankestijn PJ, Nubé MJ, Grassmann A, Canaud B, Gandjour A: Cost-effectiveness analysis of high-efficiency hemodiafiltration versus low-flux hemodialysis based on the Canadian arm of the CONTRAST study. Appl Health Econ Health Policy 2015, Epub ahead of print.
Kim JC, Garzotto F, Cruz DN, Goh CY, Nalesso F, Kim JH, Kang E, Kim HC, RoncoC: Enhancement of solute removal in a hollow-fiber hemodialyzer by mechanical vibration. Blood Purif2011;31:227-234.
Kim JC, Kim JH, Sung J, Kim HC, Kang E, Lee SH, Kim JK, Kim HC, Min BG, Ronco C: Effects of arterial port design on blood flow distribution in hemodialyzers. Blood Purif2009;28:260-267.
Kim JC, Kim JH, Kim HC, Kang E, Kim KG, Kim HC, Min BG, Ronco C: Effect of fiber structure on dialysate flow profile and hollow-fiber hemodialyzer reliability: CT perfusion study. Int J Artif Organs 2008;31:944-950.
Martín-Malo A, Aljama P: On-line hemodiafiltration reduces the proinflammatory CD14+CD16+ monocyte-derived dendritic cells: a prospective, crossover study. J Am Soc Nephrol 2006;17:2315-2321.
Henderson LW, Beans E: Successful production of sterile pyrogen-free electrolyte solution by ultrafiltration. Kidney Int 1978;14:522-525.
Henderson LW, Sanfelippo ML, Beans E: ‘On line' preparation of sterile pyrogen-free electrolyte solution. Trans Am Soc Artif Intern Organs 1978;24:465-467.
Canaud B: Online hemodiafiltration. Technical options and best clinical practices. Contrib Nephrol 2007;158:110-122.
Roy T: Technical and microbiological safety of online hemodiafiltration: a European perspective. Semin Dialysis 1999;12:S81-S87.
Canaud B, Mion C: Water treatment for contemporary hemodialysis; in Jacobs C, Kjellstrand CM, Koch KM, Winchester JF (eds): Replacement of Renal Function by Dialysis, ed 4. Dordrecht, Kluwer Academic Publishers, 1996, vol 8, pp 232-255.
Draghici, D. A., Pantea, I., Roman, N., Druguș, D., & Repanovici, A. (2023). In Vitro Mechanism Whit Pulsative Laser on Thrombolysis. Acta Technica Napocensis-Series: Applied Mathematics, Mechanics, and Engineering, 65(3S).
Refbacks
- There are currently no refbacks.