EVALUATION OF VOLUMETRIC CALIBRATION FOR DIMENSIONAL ACCURACY IN X-RAY AND NEUTRON COMPUTED TOMOGRAPHY
Abstract
Tomographic imaging employs penetrating radiation to reconstruct three-dimensional representations of internal structures. Common radiation sources include X-rays and neutrons, with X-ray computed tomography (XCT) being the most widely utilized modality. Although XCT is extensively applied in industrial dimensional metrology, its measurement uncertainty is not yet fully characterized. Calibration phantoms—typically consisting of calibrated multi-sphere artifacts—serve a critical role in enhancing traceability and measurement accuracy. These phantoms facilitate volumetric calibration, wherein the reconstructed voxel volume is scaled linearly based on known reference distances between sphere centerpoints. This study investigates the influence of volumetric calibration on the dimensional accuracy of both XCT and neutron computed tomography (NCT) systems, employing a custom-designed phantom compatible with both modalities. Experimental evaluations were conducted using two XCT systems, one of which is metrology-grade, and an NCT system. The findings indicate that while volumetric calibration ensures metrological traceability, its effectiveness in reducing measurement error is dependent on the specific system configuration.
Full Text:
PDFReferences
Waring, C. S., Bax, J. S., Samarabandu, A., Holdsworth, D. W., Fenster, A., & Lacefield, J. C. (2012). Traceable micro‐CT scaling accuracy phantom for applications requiring exact measurement of distances or volumes. Medical Physics, 39(10), 6022-6027.
Dao, A., & Drégelyi-Kiss, Á. (2020, June). Determination of GD&T Features Varying the Setting Parameters of X-Ray Computed Tomography by Response Surface Method. In Materials Science Forum (Vol. 994, pp. 280-287). Trans Tech Publications Ltd.
Marczis, A., Odrobina, M., & Drégelyi-Kiss, Á. (2024). Computed tomography as distortion mitigation method for selective laser sintering mass production. The International Journal of Advanced Manufacturing Technology, 133(9), 4845-4864.
Marczis, A., Kis, Z., & Drégelyi-Kiss, Á. (2023, October). On the Material Selection of Gauge for the Comparison of X-Ray and Neutron Tomography. In The International Symposium for Production Research (pp. 275-285). Cham: Springer Nature Switzerland.
Drégelyi-Kiss, Á. (2019, May). Towards Traceable Dimensional Measurements by Micro Computed Tomography. In International Conference on Measurement and Quality Control-Cyber Physical Issue (pp. 247-254). Cham: Springer International Publishing.
Duan, X., Cai, J., Ling, Q., Huang, Y., Qi, H., Chen, Y., ... & Xu, Y. (2021). Knowledge-based self-calibration method of calibration phantom by and for accurate robot-based CT imaging systems. Knowledge-Based Systems, 229, 107343.
Xiao, K., Han, Y., Xi, X., Bu, H., Li, L., Yan, B., ... & Liu, J. (2017, October). An optimized acquisition approach exploiting geometrical calibration in x-ray cone-beam computed tomography. In AOPC 2017: Optical Sensing and Imaging Technology and Applications (Vol. 10462, pp. 1266-1270). SPIE.
Oksuz, I., Bisbee, M., Cherepy, N., Hall, J., Townsend, A., Tringe, J., & Cao, L. (2022). Demonstration of fast neutron tomography for complex objects at sub-mm resolution. Journal of Radioanalytical and Nuclear Chemistry, 331(12), 5095-5100.
Su, S., Dai, N., Cheng, X., Zhou, X., Wang, L., & Villarraga-Gómez, H. (2020). A study on factors influencing the accuracy evaluation of dimensional X-ray computed tomography with multi-sphere standards. International Journal of Precision Engineering and Manufacturing, 21, 649-661.
Hardner, M., Liebold, F., Wagner, F., & Maas, H. G. (2024). Investigations into the geometric calibration and systematic effects of a micro-CT system. Sensors, 24(16), 5139.
Zemek, M., Blažek, P., Šrámek, J., Šalplachta, J., Zikmund, T., Klapetek, P., ... & Kaiser, J. (2020, February). Voxel size calibration for high-resolution CT. In 10th Conference on Industrial Computed Tomography (iCT) (p. 8).
Refbacks
- There are currently no refbacks.