MODULAR DESIGN OF A PARALLEL ROBOTIC STRUCTURE FOR BRACHYTHERAPY
Abstract
The paper presents design and constructive issues of a parallel robot used for brachytherapy. The medical procedure of brachytherapy implies the placement of radioactive capsules via needles inside the cancerous tissues and demands a high placement precision and several medical conditions, coming from procedural and safety necessities. Thus the robotic structure presented has been engineered for the given task through a set of design parameters and chosen mechanical joints.
Key words: Brachytherapy, Parallel robot, Structural design, Mechanical design,
Full Text:
PDFReferences
Podder TK, Beaulieu L, Caldwell B, Cormack RA, Crass JB, Dicker AP, Fenster A, Fichtinger G, Meltsner MA, Moerland MA, Nath R, Rivard MJ, Salcudean T, Song DY, Thomadsen BR, Yu Y. AAPM and GEC-ESTRO guidelines for image-guided robotic brachytherapy: Report of Task Group 192. s.l. : Med Phys., 2014 Oct. 41(10):101501. doi: 10.1118/1.4895013..
T. K. Podder, I. Buzurovic, K. Huang, T. Showalter and A. P. Dicker. Reliability of EUCLIDIAN: An autonomous robotic system for image-guided prostate brachytherapy. Brussels : Med. Phys., 2005.
Multi-channel robotic system for prostate brachytherapy. Podder, T. K., Ng, W. S. and Y. Yu. s.l. : International Conference of the IEEE Engineering in Medicine and biology Society, Lyon, France. Conf Proc IEEE Eng Med Biol Soc. 2007;2007:1233-6. pp. 1233–1236..
M. Meltsner, N. Ferrier, and B. Thomadsen. Performance evaluation and optimization of a novel brachytherapy robot. s.l. : Med. Phys., 2006. 33, 2264 (2006)..
MRI Stealth robot for prostate interventions. Stoianovici, D. and colab. s.l. : Minim. Invasiv. Ther. Allied. Technol.16, 241–248, Minim Invasive Ther Allied Technol. 2007;16(4):241-8.
al., Tokuda et. Preclinical evaluation of an MRI-compatible pneumatic robot for angulated needle placement in transperineal prostate interventions. s.l. : Int. J. Comput. Assist. Radiol. Surg. 7(6), 949–957 (2012)..
Plitea, N., Pȋslă, D., Vaida, C., Gherman, B., Szilághyi , A., Galdău, B., Cocorean D. Robot paralel pentru brahiterapie cu două lanţuri cinematice de ghidare a platformei (acului) de tip CYL-U. Număr patent: RO129698-A2 (2014)..
D. Pisla, D. Cocorean, C. Vaida, B. Gherman, A. Pisla, N. Plitea. Application Oriented Design and Simulation of an Innovative Parallel Robot for Brachytherapy. s.l. : Buffalo, New York, USA; Proc. of the ASME 2014 International Design Engineering Technical Conferences and Computers and Information in Engineering Conference - IDETC/CIE, 17 - 20 August 2014.
Refbacks