DESIGN OF CUSTOMIZED IMPLANT SLM MANUFACTURED
Abstract
Additive manufacturing has the potential to change how customized implants are fabricated but challenges remain. The present work aimed to reduce the weight of a facial titanium implant and to fabricate it by selective laser melting (SLM) process. Finite element analyses (FEA) were used to determine the von Mises stress and total deformation, applying loads from 0.5 kN to 5 kN. The results show that loads over 1.5kN distributed high von Mises tensions beyond 1000 MPa, value which was considered the yield point of titanium alloy (Ti6Al4V). The proposed redesigned model was 10% lighter and the FEA simulations reveal that the von Mises stress and total deformation are similar in both models (initial vs. redesigned). The polished SLM surfaces significantly reduce the roughness. The Sa roughness parameter calculated on the unpolished areas was 27-35 µm and on polished areas between 3 to 5 µm. Additionally, a lightweight concept with integrated lattice structures is presented. Future work is required to develop and test (mechanical and biological), new design concepts for facial implants.
Full Text:
PDFReferences
Cosma, C., Balc, N., Moldovan, M., Berce, P., Advanced Industrial Engineering – New Tendencies in Material Engineering, Chapter 2 and Chapter 3, Bielsko – Biala, Poland, 2017.
Cosma, C., Balc, N., Berce, P., Popan, A., Cosma, A., Burde, A., Direct Manufacturing of Customized implants from Biometals, by 3D Printing, Academic Journal of Manufacturing Engineering, vol. 15, 2017.
Li, W., Li, Y., Huang, G., Wu, S., Liu, W., Guo, C., Research and Development Status of Selective Laser melting (SLM), Preprints 2023.
Gao, B., Zhao, H., Peng, L., Sun, Z., Review of Research Progress in Selective Laser Melting (SLM), Micromachines vol. 14, 2023, 57.
Gibson, I., Rosen, D., Stucker, B., Additive Manufacturing Technologies: 3D Printing, Rapid Prototyping, and Direct Digital Manufacturing, Springer New York, 2014. doi.org/10.1007/978-1-4939-2113-3.
Rotaru, H., Schumacher, R., Kim, S.G., Dinu C., Selective laser melted titanium implants: a new technique for the reconstruction of extensive zygomatic complex defects, Maxillofac Plast Reconstr Surg., vol. 29, 2015. doi: 10.1186/s40902-015-0001-9.
Armencea, G., Cosma, C., et al., Technical queries of a 3D design custom-made implant made form titanium particles for maxillofacial bone reconstruction, Particulate Science and Technology, vol. 38, 2020.
George, M., Aroom, K.R., Hawes, H.G., Gill, B.S., Love, J., 3D Printed Surgical Instruments: The Design and Fabrication Process, World J Surg., vol. 41(1), 2017. doi:10.1007/s00268-016-3814-5.
Chandra, G., Pandey, A., Design approaches and challenges for biodegradable bone implants: a review, Expert Review of Medical Devices, vol. 18:7, 2021.
Hendea, R.E., Raducanu, D., Claver, A., García, J.A., Cojocaru, V.D., Nocivin, A., Stanciu, D., Serban, N., Ivanescu, S., Trisca-Rusu, C., et al., Biodegradable Magnesium Alloys for Personalised Temporary Implants, J. Funct. Biomater., vol. 14, 2023, 400.
Raducanu, D., Cojocaru, V.D., Nocivin, A., Hendea, R., Ivanescu, S., Stanciu, D., Trisca-Rusu, C., Drob, S., Cojocaru, E.M., Mechanical Alloying Process Applied for Obtaining a New Biodegradable Mg-xZn-Zr-Ca Alloy. Metals, vol. 12, 2022.
Leordean, D., Vilau, C., Dudescu, M.C., Generation of Computational 3D Models of Human Bones Based on STL Data and CAD Software Packages, Appl. Sci. vol. 11, 2021.
Madenci, E., Guven, I., The finite element method and applications in engineering using Ansys, Springer US, 2006.
Popan, I.A., Balc, N., Popan, A., Fratila, D., Trif, A. Surface roughness prediction during dry turning of austenitic stainless steel AISI 304, Appl. Mech. Mater., vol. 808, 2015.
Panc, N., Contiu, G., Bocanet, V., Thurn, L., Sabau, E., The influence of cutting technology on surface wear hardness, Academic Journal of Manufacturing Engineering, vol. 17 (3), 205-210, 2019.
Monkova, K., Monka, P., Pantazopoulos, G.A., Toulfatzis, A.I., Šmeringaiová, A., Török, J., Papadopoulou, S., Effect of Crosshead Speed and Volume Ratio on Compressive Mechanical Properties of Mono- and Double-Gyroid Structures Made of Inconel 718, Materials, vol. 16, 2023, doi.org/10.3390/ma16144973.
Trif, A., Nedezki, C.M., Bugnar, F., Particularities of the turning process for the titanium alloy Ti6Al4V, Academic Journal of Manufacturing Engineering, vol. 15(2), 2017.
Buican, G.R., Oancea, G., Martins, R.F., Study on SLM manufacturing of teeth used for dental tools testing, MATEC Web of Conf., vol. 94, 2017.
Birleanu, C., Pustan, M., Cioaza, M., Molea, A., Popa, F., Contiu, G., Effect of TiO2 nanoparticles on the tribological properties of lubricating oil: an experimental investigation, Sci Rep. vol. 12, 2022, 5201.
Soporan, V.F., Lehene, T.R., Pădureţu, S., Gabor, T., Crişan, M., Considerations on the mechanisms for optimizing the relationship between the science and engineering of metallic materials from the perspective of the professional development at university level, Mater. Sci. Eng., vol. 572, 2019.
Curaj, A., Paunica, M., Popa, A., Holeab, C., Jora, O.D., Sustainability Through Directed Change in the Visionary University: From Predicting to Producing the Future. Amfiteatru Econ., vol. 22, 2020.
Moldovan, M., Dudea, D., Cuc, S., Sarosi, C., Prodan, D., et al., Chemical and Structural Assessment of New Dental Composites with Graphene Exposed to Staining Agents, J. Funct. Biomater. vol. 14, 163, 2023.
Ulmeanu, M.E., Mateș, I.M., Doicin, C.V., Mitrică, M., et al., Bespoke Implants for Cranial Reconstructions: Preoperative to Postoperative Surgery Management System, Bioengineering vol. 10, 2023, 544.
Lietaert, K., Cutolo, A., Boey, D., Van Hooreweder, B., Fatigue life of additively manufactured Ti6Al4V scaffolds under tension-tension, tension-compression and compression-compression fatigue load, Nature Sci. Report, vol. 8, 2018, 4957.
Refbacks
- There are currently no refbacks.